Chất liệu và nguyên liệu cách XLPE nhôm Conductor dây cáp điện
Cảng: | Qingdao or Shanghai Port or as your request |
Điều Khoản Thanh Toán: | L/C,T/T |
Khả Năng Cung Cấp: | 50000 Metric Tôn / tấn Metric mỗi Month |
Nơi xuất xứ: | Henan Trung Quốc |
Nhãn hiệu: | Yifang cáp |
Model: | yjv32 yjv22 yjv |
Vật liệu cách điện: | XLPE |
Loại: | điện áp thấp hoặc trung bình điện áp hoặc điện áp cao |
Ứng dụng: | Xây dựng |
Conductor Vật liệu: | đồng hoặc nhôm |
Jacket: | PVC |
màu: | khác nhau |
Chi Tiết Giao Hàng: | Vòng 10 ngày một hộp đựng cho trẻ em |
Chi Tiết Đóng Gói: | Nhà sản xuất thép tiêu chuẩn trống hoặc request bằng gỗ |
Aluminum Conductor Material and XLPE Insulation Material Power Cable
Black PVC sheath XLPE insulated steel wire armored copper power cable YJV22 YJV32- 0.6/1KV cable
NYY,NAYY,YVV,NYCY,NYRY,NA2XY,YE3SV,YE2SHSV,NAYCVVY,NA2XY,N2XY,N2XRY Cable
Voltage:0.6/1kV,3.6/6kV;6/10KV;8.7/15KV;12/20KV;18/20KV;21/35KV;26/35KV
Conductor:
Solid or stranded Copper/Aluminum
-Insulation:
Cross-linked polyethylene( XLPE or PVC)
-Circuit Indentation:
The insulation shall be red, black
-Filler:
Polypropylene lament with lapped binding tape
-Inner Sheath:
Polyvinyl chloride (Black)
-Armor:
Galvanized steel wire/steel tape/Unarmored/Aluminum wire
-Core-covering:
Binding tape
-Outer Sheath:
Polyvinyl chloride (Black)
-Application:
For use in ducts, trays and direct burial in ground. The cable is subject to immerse in water all the time.
-Standards:
IEC 60502-1
3. Specification:
Type |
Designation |
Application |
VV |
Copper conductor ,PVC insulated ,PVC sheathed power cable |
For laying indoors, in tunnel or cable trench,unable to bear extermal mechanical forces. Single core cable is not permissible to lay in magnetic duct |
VLV |
Aluminium conductor ,PVC insulated ,PVC sheathed power cable |
|
VY |
Copper conductor, PVC insulated, PE sheathed power cable |
|
VLY |
Aluminium conductor ,PVC insulated ,PE sheathed power cable |
|
VV22 |
Copper conductor ,PVC insulated ,steel tape armoured ,PVC sheathed power cable |
For laying indoors, in cable trench or direct in ground ,able to bear external mechanical forces, but unable to bear pulling force |
VLV22 |
Aluminium conductor ,PVC insulated ,steel tape armoured ,PVC sheathed power cable |
|
VV23 |
Copper conductor ,PVC insualted ,steel tape armoured ,PE sheathed power cable |
|
VLV23 |
Alunminium conductor ,PVC insulated ,steel tape armoured ,PE sheathed power cable |
|
VV32 |
Copper conductor, PVC insulated, steel wire armoured,PVC insulated power cable
|
For laying indoors, in cable or direct in ground ,able to bear external mechanical forces, but unable to bear large pulling forces |
VLV32 |
Aluminium conductor, PVC insulated ,steel tape armoured ,PVC sheathed power cable |
|
VV33 |
Copper conductor, PVC insulated steel wire armoured , PE sheathed power cable |
|
VLV33 |
Aluminium conductor , PVC insulated , streel wire armoured ,PE sheathed power cable |
|
Note: The armoured single core cables is only used for D.C.system. As for A.C.system,non-magnetic armored material should be applied |
4. Nominal Cross-sectional Areas:
1.5 mm2 , 2.5 mm2 ,4 mm2 , 6 mm2 , 10 mm2 , 16 mm2 ,25 mm2 , 35 mm2 , 50 mm2 ,70 mm2 , 95 mm2 ,120 mm2 ,150 mm2 ,185 mm2 ,240 mm2 ,300 mm2 400 mm2 500 mm2 630 mm2 800 mm2
5. Production Range:
single core cable from 1.5 mm2 to 800 mm2,muli-core cable from 1.5 mm2 to 400 mm2
6. Operating Characteristics:
Rated power-frequency voltage u0/u:0.6/1 KV 3.6/6KV 12/20KV 18/35KV…
Max permissible continuous operating temperature of conductor 70
Max short-circuit temperature of the conductor shall not exceed (Max 5 seconds duration): cross-section of conductor 300 mm2
The ambient temperature under installations should not be below 0
The bending radius of single core cable should not be less than 20 times of the cable diameter ,the bending radius of multi-core cable should not be less than 15 times of the cable diameter.
We can also produce many other kinds of cables according to customers requirements.